Abstract
D-Heart® is a portable, smartphone-based device, which streams tracing via Bluetooth, enabling multiple leads electrocardiograms (ECGs) acquisition, currently used in human cardiology (Maurizi et al. 2017).
The aim was to determine the accuracy of DHeart® compared with the gold standard nonportable 6lead electrocardiograph in the evaluation of cardiac rhythm in dogs.
Standard 6lead and DHeart® ECGs were acquired in conscious dogs. Concordance between methods was assessed by weighted k Cohen index, with its relative significance, taking as end point variable standard 6lead ECG group. Bland Altman method (95% confidence level) was applied for P, PR, QRS, T and QT. Since differences didn’t follow a normal distribution, a nonparametric approach was used to determine limits of agreement. P was significant when < 0.05 (Maurizi et al. 2017). Amplitude of waves was not considered because currently the software doesn’t allow voltage variation.
115 dogs of different weights and breeds admitted to the Cardiology Service of DIMEVET were enrolled. Mean age was 7,5±4 years. Most were intact males (45%, n=51). The most represented breed was mongrel (27%, n=32).
Weighted Cohen's kappa test demonstrated excellent concordance in the evaluation of the heart rhythm (0.989, p<0.001), for ST segment morphology (0.991, p<0,001) and for T wave morphology (0.838, p=0.040). There was a 100% concordance in P morphology determination. P, PR, QRS, T and QT intervals comparison with BlandAltman showed an extremely good concordance for DHeart® measurements (95% limit of agreement ±0.9 ms for P, ±10 ms for PR, ±35 ms for QRS, ±5 ms for T wave). Less concordance resulted for QT (±80 ms).
In Conclusion, DHeart® proved effective accurate recording of ECG comparable to standard 6lead electrocardiographs, opening new perspectives to improve diagnostic tools in veterinary cardiology. Future perspective will be the development of a telecardiology network and to improve arrhythmia’s diagnosis in small animal practice (Bruining et al., 2014; Haberman et al., 2015).
Riferimenti bibliografici
Bruining, N., et al., 2014. Acquisition and analysis of cardiovascular signals on smartphones: potential, pitfalls and perspectives: by the Task Force of the e-Cardiology Working Group of European Society of Cardiology. European Journal of Preventive Cardiology. 21(2 Suppl), 4-13
Haberman, Z.C., et al., 2015. Wireless Smartphone ECG Enables Large-Scale Screening in Diverse Populations. Journal of Cardiovascular Electrophysiology. 26(5), 520-6
Maurizi, N., et al., 2017. Cardiovascular screening in low-income settings using a novel 4-lead smartphone-based electrocardiograph (D-Heart®). International Journal of Cardiology. 236, 249-252.
This work is licensed under a CC BY-SA 4.0 international